<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-18 08-32-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 3/5, 41 dBuV RMC
Pilot RDS Phase Difference
6.8 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
5 kHz 77 kHz 870 28,5057
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,1 dBr 7,77 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 8:32, 18.02.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 3/5 (42 dBuV) Max at: 77 kHz MIN: 5 kHz % above 75 kHz: 28,5057 Acquired: 2025/02/18 8:31:00 Total samples: 870 Equivalent time: 0:00:43 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40 60
FM Scope MAX: 8,5 dBr MIN: 7,1 dBr AVE: 7,77 dBr % above 10,0 dBr: 0,0 Last value: 8,3 dBr (2025/02/18 8:31:00) Station: 103.10 MHz, signal: 3/5 (42 dBuV) 08:24 08:25 08:26 08:27 08:28 08:29 08:30 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality